    What crazy ass compressor needs 220V 30A? Here in Netherlands heat pump is standard as new gas connections are banned for environmental reason, and most homes heat water and the whole house on 7 kW heat, 1.5 kW electric, or about 7A on 240V.

    The backup element which only runs at extreme cold outside is a few kW yes but for hot water we just let it run dry and the tap gets colder, no big deal.

    Dedicated hot water only boilers have a 300-700W compressor and sometimes a 1.5 kW backup coil. If electrical connection is an issue, just look for a pure compressor driven boiler.

    • WxFisch@lemmy.world
      link
      fedilink
      English
      arrow-up
      1
      ·
      1 year ago

      They almost always have two high wattage resistive elements installed like a traditional electric water heater which require the 220v/30a circuit. The compressor runs on 220v but sips almost no real current while running.

      • Blaat1234@lemmy.world
        link
        fedilink
        English
        arrow-up
        1
        ·
        1 year ago

        We have two main models here, one with a sizable compressor enough to heat a whole home (7-20 kW heat) and a water tank on the side which doesn’t need resistive backup, or smaller, hybrid models that have a few hundred W compressor and maybe 1-3 kW heat output. The latter are almost all backed up by a gas boiler in a hybrid setup, usually uses zero gas until you run it dry - then the 25ish kW gas powered furnace can provide enough power to quickly fill a bath or send tons of hot water to a rain shower.