• 0 Posts
  • 3 Comments
Joined 1 year ago
cake
Cake day: July 1st, 2023

help-circle

  • So for troubleshooting purposes, I would suggest disconnecting the interconnect wire, but leaving them powered. You’ll want to reference the user guide for how to hook them up as a single station and do that. Then you can see which one is actually giving the fault.

    If none of them trigger, then the problem’s probably in the wiring. Reconnect half of them and see if it happens again. Switch halves if it doesn’t, reduce by half if it does. Keep going until you find the connection causing it.

    Keep in mind that you’ll still want the interconnect wire intact, so make sure to connect the ends together in the bays of the alarms you’re disconnecting from the interconnect network.